HFS-20014 Micro1000 Laboratory Turbidimeter, Extended Auto Ranging up to 10,000 NTU, 100 - 240Vac 60Hz.

Micro1000 Laboratory Turbidimeter, Extended Auto Ranging up to 10,000 NTU


 
Designed to provide the accuracy demanded in today’s laboratory, the Micro1000 Laboratory Ratio Turbidimeter is ready to meet the challenge. Features like the Auto Alert Calibration Prompt and the Quick Connection Lamp Module, allow for simple calibration and low maintenance. A full time ratio (color correction) mode is also featured. With a resolution of 0.0001 NTU at low turbidity readings and an extended range to 10,000 NTU, the Micro1000 Turbidimeter is an ideal and affordable tool for research as well as routine analytical measurements.

Standard Features
 
Extended Auto Ranging up to 10,000 NTU
Instrument senses turbidity level of sample and automatically adjusts to the appropriate
measurement
 
Multiple Measurement Modes
NTU, EBC, and Nephelos, FNU, and FAU
 
Auto Alert Calibration Prompt
Automatically prompts the operator to initiate simple menu-driven calibration
 
Built-in Diagnostics
Full time diagnostic software automatically monitors and detects errors
 
Reusable Calibration Standards
Quick and easy calibration across all ranges without the need to mix Formazin
 
Ratio (Color Correction)
Automatic compensation for background color

 
 
The Micro1000 Turbidimeter includes a complete set of Calibration Standards (0.02 - 1750 NTU), two measuring cuvettes with light shield caps, operator's manual and plug-in power supply.
 
Note: The Micro1000 meets performance criteria specified by USEPA method 180.1 for NTU measurement and ISO7027 (IR version).
 
 
Micro1000 Specifications:
Range 0 - 10,000 NTU
0 - 2,450 EBC
0 - 10,000 FNU
0 - 10,000 FAU
Principal of Operation Nephelometric
Ratio (Color Correction) Full Time ON or OFF
Accuracy ± 2% of reading plus 0.01 NTU (0 to 1000 NTU)
± 5% of reading (1000 to 4000 NTU)
± 10% of reading (4000 to 10,000 NTU)
Resolution 0.0001 NTU on Lowest Range
Response Time Less than 6 seconds
Sample Size 30 ml
Light Source Quick Connect Tungsten Filament or Infrared
Operating Temperature 32° - 122°F (0° - 50°C)
Air Purge Connection for external dry air supply
Outputs RS-232 Serial Port (Bidirectional)
Shipping Dimensions 14 x 12 x 12 inches (35.5 x 30.4 x 30.5 cm)
Weight 7.0 lbs. (3.18 kg)
Certification UL, CSA, CE, USEPA, ISO7027
 
 
 
 
 
 
Catalog # Product Description Price
HFS-20014 Micro1000 Laboratory Turbidimeter, Extended Auto Ranging up to 10,000 NTU By Quote Only
Keyword/Catalog #:  

Items in your Cart: 0  

Current Subtotal:$0.00


Checkout Button

Coal Laboratory

Water Testing

Environmental

General Laboratory

Microgripper


Request a Quote

EZ Order

Catalog #/Cross Reference

Manufacturers

Literature

Promotions

ISO Certificate

Certificate of Analysis

MSDS