91-2599-02 Calibration Check pH Meter, with Logging of up to 500 Samples

Calibration Check pH Meter, with Logging of up to 500 Samples, Hanna HI 223


A pH electrode that is properly manufactured and kept clean will retain its measuring integrity for quite a long time. The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note because, during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset of approximately ±60 mV. The deviation from 0 mV is not unusual, in fact it represents the true characteristics of the pH electrode. The deviation from 0 mV becomes a problem if it is the result of calibrating a dirty electrode.

This pH meter compares the characteristics of the pH electrode from one calibration to the next. In case of large variances in the electrode condition that can only be the result of a soiled sensor, these meters alert the user that the electrode needs to be properly cleaned prior to calibration and measuring.

Features
  •  Enhanced Calibration Messages
  •  Electrode Condition on LCD Display
  •  Electrode Response Time on LCD Display
  •  Calibration Alarm Time Out
Specifications

Range
pH
-2.00 to 16.00 pH; -2.000 to 16.000 pH
Range
mV
±699.9 mV; ±2000 mV
Range
Temperature
-20.0 to 120.0°C
Resolution
pH
0.01 pH; 0.001 pH
Resolution
mV
0.1 (±999.9 mV); 1 (±2000 mV)
Resolution
Temperature
0.1°C
Accuracy
pH
±0.01 pH; ±0.002 pH
Accuracy
mV
±0.2 (±699.9 mV); ±0.5 (±999.9 mV); ±1 (±2000 mV)
Accuracy
Temperature
±0.4°C
Calibration Check
 
status of electrode condition and response time,
status of the buffer solution during calibration
pH Calibration
 
automatic, up to 5 points with 7 memorized values
(pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Temperature Compensation
 
manual or automatic, -20.0 to -120.0°C (-4 to 248°F)
pH Electrode
 
HI 1131P, glass-body, single junction, refillable,
BNC + Pin connector, 1 m (3.3') cable (included)
Temperature Probe
 
HI 7669/2W with 1 m (3.3') cable (included)
PC Connection
 
RS232 opto-isolated serial port
Data Logging
 
500 samples
Input Impedance
 
1012 Ohm
Power Supply
 
12 Vdc adapter (included)
Environment
 
0 to 50°C (32 to 122°F); RH max 95%
Dimensions
 
240 x 182 x 74 mm (9.4 x 7.2 x 2.9")
Weight
 
1.1 kg (2.4 lb.)
 
 
 
 
 
Catalog # Product Description Price
91-2599-02 Calibration Check pH Meter, with Logging of up to 500 Samples, Hanna HI 223 By Quote Only
Keyword/Catalog #:  

Items in your Cart: 0  

Current Subtotal:$0.00


Checkout Button

Coal Laboratory

Water Testing

Environmental

General Laboratory

Microgripper


Request a Quote

EZ Order

Catalog #/Cross Reference

Manufacturers

Literature

Promotions

ISO Certificate

Certificate of Analysis

MSDS