91-2599-02 Calibration Check pH Meter, with Logging of up to 500 Samples
Calibration Check pH Meter, with Logging of up to 500 Samples, Hanna HI 223
A pH electrode that is properly manufactured and kept clean will retain its measuring integrity for quite a long time. The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note because, during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset of approximately ±60 mV. The deviation from 0 mV is not unusual, in fact it represents the true characteristics of the pH electrode. The deviation from 0 mV becomes a problem if it is the result of calibrating a dirty electrode.
This pH meter compares the characteristics of the pH electrode from one calibration to the next. In case of large variances in the electrode condition that can only be the result of a soiled sensor, these meters alert the user that the electrode needs to be properly cleaned prior to calibration and measuring.
Features
- Enhanced Calibration Messages
- Electrode Condition on LCD Display
- Electrode Response Time on LCD Display
- Calibration Alarm Time Out
Specifications
|
Range
|
pH
|
-2.00 to 16.00 pH; -2.000 to 16.000 pH
|
|
Range
|
mV
|
±699.9 mV; ±2000 mV
|
|
Range
|
Temperature
|
-20.0 to 120.0°C
|
|
Resolution
|
pH
|
0.01 pH; 0.001 pH
|
|
Resolution
|
mV
|
0.1 (±999.9 mV); 1 (±2000 mV)
|
|
Resolution
|
Temperature
|
0.1°C
|
|
Accuracy
|
pH
|
±0.01 pH; ±0.002 pH
|
|
Accuracy
|
mV
|
±0.2 (±699.9 mV); ±0.5 (±999.9 mV); ±1 (±2000 mV)
|
|
Accuracy
|
Temperature
|
±0.4°C
|
|
Calibration Check
|
|
status of electrode condition and response time,
status of the buffer solution during calibration
|
|
pH Calibration
|
|
automatic, up to 5 points with 7 memorized values
(pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
|
|
Temperature Compensation
|
|
manual or automatic, -20.0 to -120.0°C (-4 to 248°F)
|
|
pH Electrode
|
|
HI 1131P, glass-body, single junction, refillable,
BNC + Pin connector, 1 m (3.3') cable (included)
|
|
Temperature Probe
|
|
HI 7669/2W with 1 m (3.3') cable (included)
|
|
PC Connection
|
|
RS232 opto-isolated serial port
|
|
Data Logging
|
|
500 samples
|
|
Input Impedance
|
|
1012 Ohm
|
|
Power Supply
|
|
12 Vdc adapter (included)
|
|
Environment
|
|
0 to 50°C (32 to 122°F); RH max 95%
|
|
Dimensions
|
|
240 x 182 x 74 mm (9.4 x 7.2 x 2.9")
|
|
Weight
|
|
1.1 kg (2.4 lb.)
|
| Catalog # |
Product Description |
|
Price |
|
91-2599-02
|
Calibration Check pH Meter, with Logging of up to 500 Samples, Hanna HI 223
|
By Quote Only
|
|
|
|